- Refrigerated Air Dryer
- Air Filter
- Extractor Dryer
- Air Tubing / Air Hose / Copper Tubing
- Push In Fitting / Brass Fitting / Ouick Coupler
- Push In Fitting
- Brass Fitting
- 0206 - Allen Key Plug
- 160 - Sleeve
- 162 - Union
- 164 - Tee Union
- 166 - Female Connector
- 168 - Male Connector
- 169 - Male Connector Elbow
- 71 - Taper Plug
- 71F - Female Plug
- 72 - Adaptor
- 73 - Reducing Bush
- 74 - Hexagon Socket
- 76 - Nipple
- 77 - Reducer Nipple
- 78 - Male/Female Elbow
- 79 - Female Elbow
- 80 - Female Tee
- 81 - Tail Piece
- 82 - Female Tail Piece
- 82 - Female Tail Piece(PCK)
- 84 - Joiner
- 86 - Tee Joiner
- 89 - Y Joiner
- 92 - Male Elbow
- 94 - Male Branch Tee
- L83 - Tail Piece Elbow
- Compression Fitting
- Coupler
- Silencer
- Others
- Pneumatic Components
- Clean Air Unit
- Control Valve
- Check Valve
- Cylinder
- Standard Cylinder
- Mini Cylinder
- Compact Cylinder
- Mini Free Mount and Multi-mount Cylinder
- Plate and Threaded Cylinder
- Twin-rod Cylinder
- Tri-rod Cylinder
- Slide Table and Compact Slide Cylinder
- Rodless Magnetic and Rotary Table Cylinder
- Air Gripper Series
- Clamp Series Cylinder
- Stopper Cylinder
- Chelic Compact Air Cylinder
- Cylinder Accessories
- Chelic
- Airtac
- CKD
- Festo
- SMC
- Condensate Drain
- More Products
Prominent Supplies (M)
Sdn Bhd
58-G, Jalan Nagasari 1,
Taman Nagasari,
13600 Perai,
Pulau Pinang, Malaysia.
+604-305 1055
+604-399 6355
MG SEries
Previous | 1 / 6 | Next |
Product Feature
1.JIS standard is implemented.
2.Piston adopts heterogeneous two way seal structure. It has compact size and has the function of oil reservation.
3.Front cover owns fixed anti-impact pad which can reduce the impact of direction-change of the cylinder.
4.Front and back cover and stainless steel block adopt riveted rolling packed structure to form a reliable connection.
5.The cylinder body has stainless steel pipes with high precision to produce high strength and corrosion resistance.
6.There are cylinders and mounting accessories with several specifications for your choice1.JIS standard is implemented.
Specification
Installation & Usage
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.To avoid side load, otherwise, piston rod will be bent and deformed and damage the thread at the end of the rod. Single-acting type can not be added in return.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports. The front and back cover can not be dismantled, which shall be especially noticed.
Ordering Code
Symbol
1.JIS standard is implemented.
2.Piston adopts heterogeneous two way seal structure. It has compact size and has the function of oil reservation.
3.Front cover owns fixed anti-impact pad which can reduce the impact of direction-change of the cylinder.
4.Front and back cover and stainless steel block adopt riveted rolling packed structure to form a reliable connection.
5.The cylinder body has stainless steel pipes with high precision to produce high strength and corrosion resistance.
6.There are cylinders and mounting accessories with several specifications for your choice1.JIS standard is implemented.
Specification
Installation & Usage
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.To avoid side load, otherwise, piston rod will be bent and deformed and damage the thread at the end of the rod. Single-acting type can not be added in return.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports. The front and back cover can not be dismantled, which shall be especially noticed.
Ordering Code
Symbol